HV-001 CLASSIFIED PATREON TIER 2+ REV 1.0 · OCT 2025
MARX
GENERATOR
Chapter 1 · Design, Construction & Operation · 14-Stage · ~100–120kV Impulse

A comprehensive documentation of a 14-stage Marx impulse generator — from first principles through power supply selection, mechanical construction, commissioning, and troubleshooting. Four power supplies were destroyed getting the design right. That story is in this document, exactly as it happened.

Stages14
Theoretical V140kV
Actual V~100–120kV
Stored Energy0.55 J
Charge Time τ~1.6 sec
Build Cost$451–685
STL FilesAvailable
1.1 Introduction and Scope
INTRODUCTION
⚠️
LETHAL VOLTAGE — MANDATORY SAFETY WARNING This document describes construction of equipment producing voltages exceeding 100,000 volts. Current as low as 10–20 milliamps across the heart causes ventricular fibrillation. High-voltage arcs jump significant distances through air. Capacitors retain lethal charge after power removal. Secondary X-ray generation may occur above 15kV. Read Section 1.2 in full before proceeding. The author and SpaceCommsKit assume no liability for injury, death, or property damage. YOU PROCEED ENTIRELY AT YOUR OWN RISK.

This chapter presents a comprehensive guide to the design, construction, and operation of Marx impulse generators — devices capable of generating extremely high-voltage electrical pulses from relatively modest DC power sources. Named after German physicist Erwin Marx who developed the concept in 1924, these circuits have found applications ranging from EMP testing and materials research to advanced physics experiments.

The design documented here is a 14-stage implementation producing pulses in excess of 100 kilovolts. Sufficient technical detail is provided to enable a knowledgeable practitioner to replicate the design — including the complete account of why four different power supplies were destroyed in the process, and what finally worked.

📖
DOCUMENT PHILOSOPHY "My only hope would be to make as few mistakes as possible and to describe my outcomes as specifically as possible. There is no good or bad outcome, there is only an outcome with as much detail in the process and observations as one can give with the setting and equipment they have at their disposal." Readers are encouraged to verify all claims through independent testing and contribute findings back to the community.
Applications and Motivation
  • ⚡
    EMP Testing — Simulating electromagnetic pulse effects on electronic systems and shielding
  • ⚡
    Materials Research — Dielectric breakdown studies in insulators, polymers, and novel composites
  • ⚡
    Plasma Generation — High-energy plasma creation for spectroscopy and surface treatment
  • ⚡
    Advanced Physics — Investigation of impulse-related phenomena including Podkletnov gravity modification hypotheses
  • ⚡
    HV Engineering Education — Demonstration of charge multiplication, Paschen's Law, and pulsed power systems
🔬
RESEARCH CONTEXT Several researchers have explored the relationship between high-voltage pulsed systems and gravitational effects — including Eugene Podkletnov's impulse gravity generator and replications by Tony Robertson and Dr. Chance Glenn. These claims remain controversial in mainstream physics but represent a genuinely interesting avenue for well-equipped experimental investigation. The advanced physics connection is documented in Section 1.10.
1.2 Comprehensive Safety Framework
SAFETY
☠️
READ THIS ENTIRE SECTION BEFORE ANY CONSTRUCTION BEGINS High voltage does not warn you. The following protocols are not suggestions — they are the minimum requirements for surviving this project.
Workspace Requirements
  • ▸
    Dedicated, isolated workspace — away from living areas, children, and pets
  • ▸
    Non-conductive flooring — rubber mats minimum; dedicated insulated floor preferred
  • ▸
    Minimum 3-foot clearance on all sides of the generator during energized operation
  • ▸
    CO₂ or ABC fire extinguisher — accessible without approaching the generator
  • ▸
    Emergency shutoff within reach — never require approach to the generator to cut power
  • ▸
    Ventilation — ozone from sustained arcing is a respiratory hazard
  • ▸
    Bright overhead lighting — clearly see all connections and potential hazards
Personal Protective Equipment
EquipmentSpecificationPurpose
Safety GlassesANSI Z87.1+ ratedArc flash and debris
Face ShieldFull face, polycarbonateArc flash protection — worn over glasses
Insulating GlovesClass 2, 17kV rated minimumElectrical insulation during testing
FootwearRubber-soled, closed-toe, non-conductiveFloor insulation
RespiratorP100 or equivalentOzone and combustion products
Capacitor Discharge Protocol — Non-Negotiable
🔋
HIGH-VOLTAGE CAPACITORS RETAIN LETHAL CHARGE FOR HOURS AFTER POWER REMOVAL Treat every capacitor as charged until you have personally discharged and verified it with a calibrated HV probe. Installing shorting jumpers before physical contact is mandatory.
  1. 01Remove all power. Wait minimum 5 minutes.
  2. 02Use a 1MΩ, 10W resistor on an insulated handle — short each capacitor terminal to ground through it.
  3. 03Verify zero voltage with calibrated HV probe at every capacitor terminal.
  4. 04Install shorting jumpers on all capacitors before any physical approach.
  5. 05Never touch terminals directly even after discharge. Make this a reflex, not a decision.
Emergency Procedures
🚨
ELECTRICAL SHOCK RESPONSE DO NOT TOUCH THE VICTIM until power is confirmed off. Cut power immediately via emergency shutoff. Call 911. Begin CPR only after power is confirmed off. Even an apparently unharmed victim must receive immediate medical evaluation — high-voltage shock can cause delayed cardiac and tissue damage.
⚠️
BERYLLIUM HAZARD — MICROWAVE MAGNETRONS Magnetrons contain beryllium ceramic components. If damaged, beryllium dust causes fatal progressive lung disease. Never break, grind, or damage magnetrons. If breakage occurs, evacuate and consult hazmat disposal procedures.
⚡
GROUNDING ISOLATION — CRITICAL The Marx ground pipe must NOT connect to building ground, water pipes, or any grounded structure. It is a floating reference for the HV circuit only. Connection to building ground creates dangerous ground loops and potential damage to household electronics and medical devices in adjacent spaces.
1.3 Theoretical Foundation
THEORY

The Marx generator solves a problem with profound elegance: how do you generate very high voltage when your power supply only produces moderate voltage? Erwin Marx's 1924 answer — charge capacitors in parallel at low voltage, then switch them into series to multiply — remains one of the most beautiful circuits in electrical engineering. The physics is simple. The construction is not.

  • 01
    CHARGING PHASE — PARALLEL CONFIGURATION
    All capacitors charge in parallel through the charging resistors. Each capacitor charges to the input voltage Vin. The resistors ensure all capacitors reach the same voltage while limiting charging current. During this phase, the circuit is deceptively quiet — all the energy accumulation is invisible, stored in electric fields inside ceramic dielectric layers.
  • 02
    DISCHARGE — CASCADE SERIES SWITCHING
    When the first spark gap reaches its breakdown voltage, it conducts and applies approximately 2Vin across the second gap, triggering it. The cascade propagates through all stages in microseconds — far faster than any mechanical switch. All capacitors are suddenly in series. The CRACK you hear is this event: a microsecond pulse of ~100kV arc energy.
// Peak Output Voltage
Vout = n × Vin
n = number of stages  |  Vin = charge voltage per stage
Practical output ≈ 0.70–0.85 × theoretical (spark gap and resistive losses)
This build: n=14, Vin=10kV → Vout(theoretical) = 140kV  |  Vout(actual) ≈ 100–120kV
// Energy Stored Per Stage
E = ½CV²
C = capacitance (Farads)  |  V = charge voltage (Volts)
780pF @ 10kV: E = ½ × 780×10⁻¹² × (10,000)² = 0.039 joules per stage
Total: 14 × 0.039J = 0.546 joules — enough to be lethal many times over
// Marx Generator Cascade — Simplified to 3 of 14 Stages
  HV IN    R₁         R₃         R₅
  (+)──┬───┤├──┬───────┤├──┬───────┤├──┬── ... ── OUTPUT(+) ~100-140kV
       │       │            │            │
      [C₁]   SG₁           [C₂]        SG₂       ... × 14 stages
       │       │            │            │
  (-)──┴───────┴────────────┴────────────┴── ... ── OUTPUT(-) = GND PIPE

  CHARGE:  C₁...C₁₄ all charge to V_in=10kV in parallel via R network
  FIRE:    SG₁ breaks at ~10kV → C₁+C₂ = ~20kV across SG₂
           SG₂ fires instantly → C₁+C₂+C₃ = ~30kV across SG₃
           Cascade continues — all 14 stages fire in microseconds
  OUTPUT:  14 × 10kV = 140kV theoretical | ~100-120kV practical
  τ_charge = R×C ≈ 2MΩ × 780pF × 14 ≈ 1.6 seconds (RC time constant)
Spark Gap Physics — Paschen's Law

The breakdown voltage of an air gap is not a fixed material constant — it depends on gap geometry, electrode surface condition, humidity, and UV illumination. For small gaps in clean dry air at atmospheric pressure, Paschen's Law gives the practical approximation:

// Approximate Air Breakdown Voltage (Small Gaps)
Vbreakdown ≈ 30 kV/cm × gap (cm)
Valid for gaps <10mm | Spherical electrodes improve uniformity and reduce field enhancement
Humidity, contamination, electrode oxidation, UV, and electrode geometry all shift the actual threshold
Gap DistanceBreakdown VoltageUse in This Design
2 mm~6 kVConservative setting — reliable but lower output
3 mm~9 kVTypical operating gap — matched to 10kV charge voltage
4 mm~12 kVHigher voltage operation — erratic firing if humidity changes
5 mm~15 kVMaximum practical — cascade reliability decreases
📐
DIELECTRIC STRENGTH OF AIR ~3 kV/mm for uniform electric fields. Drops dramatically near sharp edges (corona), on contaminated surfaces, and with elevated humidity. Always design to a 2–3× safety factor. A component rated 10kV should be operating at no more than 3.3–5kV in practice for reliable, long-term performance.
Insulation Material Selection
MaterialDielectric StrengthPractical Notes for HV
Polycarbonate~15–20 kV/mmExcellent but can become conductive when contaminated. May distort when cut.
PVC (thick wall)~12–16 kV/mmBetter shape retention after cutting. Easier to source in large diameters.
Phenolic (Garolite)~12–20 kV/mmTraditional HV material. Excellent arc resistance. Less accessible.
PETG (3D printed)~10–15 kV/mmAdequate for structural mounting fixtures. Not primary HV insulation.
FR4 PCB substrate~15 kV/mm dryAvoid at HV nodes — moisture absorption degrades performance severely.
1.4 Power Supply Design and Selection
POWER SUPPLY

The power supply proved to be the most critical and most humbling subsystem. An ideal Marx generator supply provides 10–25kV DC output, 15–20mA current minimum, immunity to EMI from its own discharge events, and current limiting for component protection. Getting all four simultaneously took four attempts and cost three destroyed supplies. Here is the complete, unedited record.

Power Supply Requirements
  • ▸
    Output voltage: 10–25 kV DC (pulsating DC acceptable)
  • ▸
    Current capability: 15–20 mA minimum for reasonable charging times
  • ▸
    EMI compatibility: Must tolerate broadband RF from Marx discharge without resetting
  • ▸
    Current limiting: Protects against component failure and arc-over events
The Four Approaches — Complete Results
ZVS driver module with flyback transformer — red PCB with inductors, MOSFETs, and black flyback transformer
Figure 1-1. ZVS driver + flyback combo. 12–30V DC input, ~10kV pulsating DC output. The HV generation stage used in all four PSU configurations.
AC flyback transformer — white body with orange coiled wire, rated 25kV AC output
Figure 1-2. Alternate: 25kV AC flyback from hv-experimental.com. True AC output allows polarity selection and dual-generator configurations.
FAILED
Variable Bench PSU
0–30V / 0–10A / 300W — switchmode with digital control panel
  • ✓ Allowed voltage and current optimization during setup
  • ✗ Reset after every Marx discharge when placed nearby
  • ✗ EMI coupling through control circuitry — unstable operation
  • ✗ Required minimum 2m separation to function at all
  • ✗ Risk of permanent microcontroller damage from repeated EMI
// VERDICT: Usable only at significant distance. Not practical for an integrated design.
DESTROYED
Shielded Switching PSU
24V DC / 15A / metal chassis with grounding and EMI filter
  • ✓ Better EMI resistance than bench supply
  • ✗ Random resets when mounted to Marx base plate
  • ✗ Voltage fluctuations during EMI events damaged flyback transformer
  • ✗ Complete system failure after extended testing session
// VERDICT: Metal shielding insufficient for pulsed operation. Voltage instability was destructive.
THERMAL FAILURE
Transformer + Rectifier
24V AC salvaged transformer + full-wave bridge rectifier, unregulated
  • ✓✓ Completely immune to EMI — no digital control to disrupt
  • ✓ Stable operation during discharges — right architecture
  • ✗ Transformer undersized for continuous 15A load
  • ✗ After 60s: transformer → rectifier → flyback cascade thermal failure
  • ✗ Complete system loss before power could be cut
// VERDICT: Correct approach, wrong implementation. Proved the architecture. Proved we needed a bigger transformer.
RECOMMENDED ✓
Rewound MOT
Microwave Oven Transformer · 15V custom secondary · 35A / 200V bridge rectifier
  • ✓✓ Completely EMI immune — iron, copper, and ceramic only in the signal path
  • ✓✓ Massively overbuilt — designed for continuous microwave magnetron operation
  • ✓✓ Free or near-free — from discarded microwaves
  • ✓ Custom rewindable — exact voltage and current to specification
  • ✓ Runs warm but well within safe temperature after extended continuous operation
// VERDICT: Zero failures through all testing. This is the one.
Variable bench power supply showing 30.00V 10.00A 300W display with control knobs
Figure 1-3. Supply #1 — Variable bench PSU. Precise control, zero EMI tolerance. Reset after every discharge.
Industrial switching power supply with metal shielded chassis and screw terminal block
Figure 1-4. Supply #2 — Shielded switching PSU. Better EMI resistance, still failed. Voltage instability destroyed the flyback.
Transformer-rectifier assembly on base plate with transformer circled in red and bridge rectifier visible
Figure 1-5. Supply #3 — Transformer + rectifier. Right architecture, undersized transformer. Thermal cascade failure at 60 seconds.
Rewound microwave oven transformer showing secondary removed, custom winding apertures visible, bridge rectifier mounted on top
Figure 1-6. Supply #4 — Rewound MOT. The winner. Zero failures through all testing. Bridge rectifier (GBPC3504) mounted on top.
MOT Rewinding Specifications

Choose a microwave that feels unexpectedly heavy when you lift it — these contain traditional laminated iron-core transformers rather than the lighter ferrite-core or switching-mode designs found in modern microwave ovens. The weight is the tell. Remove the original secondary winding (typically wound with fine wire to ~2kV) and replace it with a new secondary per the following specification:

ParameterSpecificationNotes
Primary115V AC (unchanged)Retain original primary winding — do not touch it
Secondary Voltage15–20V ACAfter rectification: ~21–28V DC unregulated
Wire Gauge#12 AWG strandedGood for 20+ amps continuous. Do not use smaller gauge.
Turns Count8–12 turnsDepends on core geometry — verify with measurement
Bridge Rectifier Rating35A, 200VLarge margin for thermal headroom and reliability
Final HV Output~10kV pulsating DCVia ZVS driver + flyback transformer stage
Salvageable Microwave Components

Every discarded microwave is a complete parts kit. Save all of these:

ComponentSpecificationUse in HV Work
MOT (Transformer)1–1.5kVA, laminated iron corePrimary target — rewind for custom HV power supply
Magnetron2.45 GHz, ~1kW outputRF generation, radar experiments, NMR research
HV Capacitor0.9–1.2µF at 2000VUseful in power supply and pulse circuit applications
HV Diode12–15kV ratedHigh-voltage rectifier for custom supplies
Waveguide sectionsPrecision machined aluminumMicrowave coupling experiments
Disassembled microwave components: transformer (green circle), HV capacitor (red circle), magnetron (orange circle), waveguide (yellow circle)
Figure 1-7. Complete salvage haul from one microwave oven. Green: MOT transformer. Red: HV capacitor (~1µF, 2kV). Orange: magnetron (2.45GHz). Yellow: waveguide sections. All typically in perfect working condition even from non-functional microwaves.
⚠️
CAPACITOR DISCHARGE MANDATORY BEFORE ANY DISASSEMBLY Short the HV capacitor terminals together using an insulated screwdriver before removing any components. The capacitor retains lethal charge indefinitely after the microwave is unplugged. Treat every microwave as if the capacitor is charged until you have personally discharged it.
1.5 High-Voltage Stack Design
HV STACK
Complete Stack Specifications — 14 Stages
ParameterValueNotes
Stage Count14Each: 1 capacitor + 2 resistors + 1 spark gap
Capacitor780 pF, 30kV doorknob ceramic1 per stage — threaded terminal for ring terminal mount
Charging Resistors1MΩ each, HV rated, 2 per stage30 total — cover all with heat shrink tubing
Spark GapsBrass sphere electrodes, 2–5mm adjustableM3 threaded brass balls, 12AWG copper support arms
Total Series Capacitance~56 pF14 caps in series: C_total = C_stage / n
Total Charging Resistance28 MΩSets RC time constant for charging cycle
Charge Time Constant τ~1.6 secondsDetermines maximum practical pulse repetition rate
Total Stored Energy~0.55 joules14 × ½ × 780pF × (10,000V)² — lethal magnitude
Theoretical Peak Output140 kV14 × 10kV per stage
Actual Measured Output100–120 kV70–85% efficiency — spark gap and resistive losses
Backbone Tube3" OD polycarbonate, 39" length35" longitudinal cutout exposes spark gaps
Why Doorknob Capacitors?
780pF 30kV doorknob high-voltage ceramic capacitor with threaded metal terminal stud
Figure 1-8. 780pF, 30kV doorknob capacitor. The ceramic dielectric offers low ESR for fast discharge. Threaded terminal stud mounts directly to a ring terminal with a machine screw. Available from surplussales.com.
3-inch clear polycarbonate tube — structural backbone of the Marx generator stack
Figure 1-9. 3" OD clear polycarbonate tube — the structural backbone. A 35" longitudinal cutout exposes the spark gaps while maintaining rigidity and full visual access to every stage.

Doorknob capacitors — named for their shape — are ceramic high-voltage pulse capacitors. The ceramic dielectric provides very low equivalent series resistance (ESR), enabling the fast, high-current discharge pulse the Marx generator demands. The physically robust ceramic body withstands mechanical shock from repeated discharge events. The threaded metal terminal stud simplifies mounting to ring terminals — a repeatable, reliable mechanical and electrical connection.

For this design: 780 pF at 30kV from Surplus Sales of Nebraska. The 30kV voltage rating provides a 3× safety factor over the 10kV operating charge voltage. This margin is real engineering, not conservatism — transient overvoltages during cascade firing briefly exceed steady-state values.

Spark Gap Construction and Electrode Physics

Each gap consists of two M3-threaded brass ball electrodes on 12 AWG solid copper support arms. Brass is preferred over steel: brass erodes more slowly and maintains a smoother spherical surface that ensures consistent electric field distribution and more repeatable breakdown voltage across hundreds of discharge events. Steel electrodes develop pits and irregular surfaces that degrade cascade consistency within tens of pulses.

⚙️
GAP UNIFORMITY IS THE SINGLE MOST CRITICAL VARIABLE IN THIS DESIGN All 14 gaps must be set to identical spacing using feeler gauges. A variation of even 0.5mm between stages can stall the cascade — the next gap won't receive enough overvoltage to fire, and the discharge stops mid-stack. This causes partial energy release, elevated stress on already-fired stages, and erratic output. Equalize gaps every session.
// Component Preparation — From Raw Parts to Finished Stage
Blue insulated ring connector terminals in packaging — 16-14 AWG, M5 size, 100 piece kit
Figure 1-10. Insulated ring terminals — the backbone of every electrical connection in this build. Every capacitor terminal, every resistor lead, every spark gap wire ends in a ring terminal on a machine screw.
Pile of M3 zinc-plated washers and lock washers on wood surface
Figure 1-11. Hardware assortment — M3 washers and lock washers. Lock washers are mandatory on all high-voltage connections. Vibration from discharge events will loosen plain fasteners over time.
Raw components laid out: black heat shrink tubing pieces, 1MΩ resistors on tape, and metal washers
Figure 1-12. Raw stage components — 1MΩ charging resistors (blue, on tape), heat shrink tubing sections, and hardware. Two resistors and one section of heat shrink per stage, 14 stages = 28 resistors minimum plus spares.
Resistors being prepped with ring terminals and heat shrink — in-progress assembly on workbench
Figure 1-13. Resistor preparation in progress. Ring terminals crimped to both leads, heat shrink positioned before shrinking. Every resistor body gets fully covered — no exposed resistor surface at high-voltage nodes.
Completed resistor assemblies with heat shrink applied and brass balls visible, plus fresh copper spark gap arms
Figure 1-14. Completed resistor assemblies (top) with heat shrink applied. Fresh copper spark gap support arms below — 12 AWG solid copper wire with ring terminals crimped. Brass electrode balls visible in packaging.
Spark gap arms and ring terminals — copper wire segments with ring terminals crimped, ready for brass ball attachment
Figure 1-15. Spark gap arm components. Uninsulated ring terminals for the spark gap connections (copper-to-copper contact required for conductivity), insulated black assemblies for the resistor-to-capacitor connections.
Completed spark gap arms — copper wire with ring terminals, ready to receive brass electrode balls
Figure 1-16. Completed spark gap support arms — all 28 pieces. Bare copper ring terminals at the ends will clamp between the brass ball M3 stud and a machine screw nut. Bare copper ensures lowest resistance contact.
Assembled spark gap units showing brass balls on copper arms with heat-shrink insulated resistor connections alongside M3 hardware
Figure 1-17. Completed spark gap assemblies with brass electrode balls installed. Left pair shows the gap electrode arms with balls. Right pair shows the heat-shrink insulated charging resistor assemblies alongside M3 hardware.
Single Marx generator stage assembled — doorknob capacitor in 3D printed mount with spark gap arms and brass balls positioned
Figure 1-18. Single completed stage — doorknob capacitor secured in its 3D-printed PETG mounting frame, spark gap arms positioned with brass electrode balls facing outward toward the ground pipe. This unit repeats 14 times up the polycarbonate backbone.
3D Printed Components — STL Files Available via Patreon

All printed parts are PETG for improved temperature resistance over PLA. These are structural components providing mounting and positioning — they do not form the primary high-voltage insulation path. All STL files available to Patreon Tier 2 subscribers via Google Drive link in the Patreon post.

ComponentMaterialQtyPrint TimeFunction
Capacitor Mounting FramePETG14~20 min ea.U-shaped mount — holds doorknob cap to backbone tube
Base Mount DiscPETG1~45 min80mm×60mm disc — mounts polycarbonate tube to base plate via ¼-20 bolt
Tube CapPETG1~30 minTop cap — base for output electrode assembly
Electrode Arm Part 1PETG1~25 minVertical adjustment arm for output electrode position
Electrode Arm Part 2PETG1~20 minElectrode arm mount bracket
Ground Pipe Support BlockPLA1~30 minFar-end stabilizer for copper ground pipe
Grounding System — Isolated Copper Pipe
Copper plumbing stub-out fitting with flat mounting bracket — the ground pipe base mount assembly
Figure 1-19. Copper ground pipe base mount — a standard plumbing stub-out fitting with a bent copper strap screwed to the base plate. Simple, zero-resistance, and completely immune to EMI. The ½" pipe attaches here and runs the full height of the stack.

A ½-inch copper plumbing pipe runs parallel to the stack, mounted vertically on the base plate via a plumbing stub-out fitting and bent copper strap. All 14 spark gap lower terminals connect to this pipe via 14 AWG copper wire. It provides the low-resistance return path for the fast, high-current discharge pulse. A 3D-printed support block stabilizes the far end.

⚡
THIS PIPE MUST REMAIN COMPLETELY ISOLATED FROM BUILDING GROUND Floating ground reference for the Marx circuit only. Connection to building electrical ground, water pipes, or any grounded structure creates unexpected current paths, damages household electronics, trips GFCIs, and introduces hazards that are not present in the isolated design.
1.6 Mechanical Construction
CONSTRUCTION
Completed 14-stage Marx generator — full assembly with polycarbonate backbone, 14 doorknob capacitor stages, brass spark gaps, copper ground pipe, and base-mounted power supply
Figure 1-20. Completed 14-stage Marx generator. Clear polycarbonate backbone housing the capacitor stack with brass spark gap arms extending outward, copper ground pipe running parallel on the left, output electrode assembly at top, and base-mounted MOT power supply. This is what we are building.
Base Plate
ParameterSpecificationNotes
Material¼" polycarbonate or ½" plywoodPolycarbonate preferred for insulation; plywood cheaper and adequate
Minimum Size24" × 18"Provides adequate clearance around all components
MountingPre-drilled, countersunk holesPrevents stress concentrations at fastener locations
FeetRubber or cork padsElevates base, provides non-slip surface and additional insulation
Complete System Layout — Bottom to Top
  • 1
    BASE LEVEL — POWER SUPPLY
    Rewound MOT + 35A bridge rectifier, input terminal block, safety ground connections. ZVS driver module and flyback transformer mounted here. HV output from flyback to Marx stack input via 18 AWG HV wire.
  • 2
    STACK BASE — FIRST STAGE
    First-stage capacitor, input charging resistors, lower electrode. 3D-printed base mount disc secures polycarbonate tube via ¼-20 bolt. Sheet metal screws secure tube to disc. Ground pipe base mount at this level.
  • 3
    STACK BODY — 39 INCHES, 14 STAGES
    14 stages — capacitor mounts bolted through polycarbonate tube wall. All resistors covered in heat shrink. Spark gap arms extend outward from tube toward ground pipe. 35" longitudinal cutout exposes spark gaps for visibility and adjustment.
  • 4
    STACK TOP — OUTPUT ELECTRODE ASSEMBLY
    3D-printed tube cap hosts electrode arm assembly. ¼-20 threaded rod provides vertical height adjustment. Phenolic tube houses 10 AWG stranded wire from final capacitor to output. Large brass ball electrode minimizes corona discharge.
  • 5
    GROUND RAIL — COPPER PIPE
    ½" copper pipe parallel to stack. Stub-out fitting and bent copper strap at base. 3D-printed support block at far end. All 14 spark gap lower terminals connect via 14 AWG wire. Provides low-resistance return path for the discharge pulse current.
Pre-Operation Alignment Checklist
  • □ Spark gaps measured and equalized with feeler gauges — all identical spacing
  • □ All capacitors perpendicular to backbone, terminals accessible
  • □ Ground rail continuity verified — <1Ω total resistance
  • □ All resistors covered with heat shrink — no exposed resistor bodies
  • □ No conductive objects within minimum clearance distances
  • □ Mechanical stability — shake test, no loose components or rattling hardware
  • □ Emergency shutoff tested and accessible
  • □ PPE in good condition and within arm's reach
  • □ Fire extinguisher accessible without approaching the generator
  • □ Second person present — never operate alone
⚠️
POLYCARBONATE DISTORTION NOTE Polycarbonate tube frequently collapses slightly inward when the longitudinal cutout is made, due to residual extrusion stress. Thick-wall PVC pipe maintains shape better after cutting and is easier to source in 3" diameter. If using polycarbonate, cut slowly and allow the material to relax before mounting components.
1.7 Commissioning and Testing
COMMISSIONING
🚨
FIRST POWER-ON PROTOCOL — NO DEVIATIONS PERMITTED The first energization is the most dangerous moment in this build. Unknown construction errors only reveal themselves under voltage. Clear all personnel to 10 feet minimum. Don full PPE. Verify emergency shutoff is in your hand. Announce "POWERING HIGH VOLTAGE" loudly. Apply power via remote switch. Retreat immediately. Observe for 30 seconds before approaching.
Progressive Power-On Sequence
  • 1
    MOT ONLY — LOW VOLTAGE VALIDATION
    Power MOT without ZVS/flyback connected. Verify rectifier output: 21–28V DC. Check for excessive heat, abnormal sounds, or burning smell. Run 60 seconds, monitor current draw. Stable → proceed to Stage 2.
  • 2
    HV GENERATION — FLYBACK ONLY, NO MARX
    Connect ZVS + flyback to power supply. Marx stack disconnected. Power on. Observe HV output with 6+ inch air gap for safety. Listen for ZVS oscillation. Observe corona or spark at HV terminal (~10kV expected). Run 30 seconds, monitor for component heating. Stable → proceed to Stage 3.
  • 3
    MARX CHARGING — SPARK GAPS AT MAXIMUM SPACING
    Connect flyback to Marx input. Set ALL spark gaps to maximum spacing — no discharge expected. Power for 10 seconds. Immediately power off and discharge all capacitors via the standard procedure. Verify capacitors charged by measuring voltage at several stages. This confirms charging works without triggering a discharge.
  • 4
    FIRST FULL DISCHARGE — THE MOMENT OF TRUTH
    Set spark gaps to operating distance (3–4mm typical). Clear area. Full PPE. Verify emergency shutoff. Power on and step back. After several seconds: expect a loud CRACK, bright arc flash, possible EMI effects (lights flickering, radio static). Allow a single discharge. Power off immediately. Wait 5 minutes. Discharge capacitors. Inspect carefully. Congratulations — welcome to pulsed power research.
Output Voltage Measurement Methods
MethodEquipment RequiredAccuracy
Spark Gap MethodCalibrated brass sphere electrodes at known spacing±15% — affected by humidity and electrode condition
HV Probe + Oscilloscope1000:1 or 10000:1 divider probe±5% — best practical method for the bench
Arc Length EstimateRuler — measure max arc to grounded target±20% — V ≈ 30kV/cm × arc length (cm)
Operating Limits
ParameterMaximumReason
Continuous Operation60 secondsMOT thermal capacity limit
Pulses per Session30–40 pulsesSpark gap electrode erosion monitoring
Daily Run Time15 minutes cumulativePrevents accelerated component aging
Ambient Temperature<30°C (86°F)Higher temps reduce cooling effectiveness
Rest Between Sessions30 minutes minimumFull thermal recovery
📊
BREAK-IN PERIOD — EXPECT FIRST 10–20 DISCHARGES TO VARY Output voltage typically increases as spark gaps stabilize and brass electrodes develop optimal surface texture. Weak connections or components may fail during break-in — this is expected and far preferable to failure during a critical experiment session. After break-in, performance stabilizes. Document every session in a test log: date, temperature, humidity, gap settings, arc length, pulse count, anomalies.
1.8 Troubleshooting Guide
TROUBLESHOOTING
Power Supply Problems
SymptomProbable CauseSolution
No HV output from flybackZVS driver not oscillatingCheck input voltage (12–30V DC required). Verify MOSFET gates. Check feedback network continuity.
Flyback arcing internallyInternal insulation failureReplace flyback transformer. Verify input voltage within rated limits.
PSU resets on Marx dischargeEMI into control circuitrySwitch to transformer-based supply (MOT). Increase separation. This is the Supply #1 and #2 problem.
Transformer overheatingUndersized for continuous loadReduce duty cycle. Upgrade to larger MOT. Verify #12 AWG secondary winding wire.
Output voltage drops under loadInsufficient current capabilityCheck wire gauge. Verify rectifier rating. Upgrade transformer if needed.
Discharge Problems
SymptomProbable CauseSolution
No discharge occursSpark gaps too wideReduce gap spacing 0.5mm at a time until cascade fires. This is almost always the first issue encountered.
Only some stages dischargeNon-uniform gap spacingMeasure every gap with feeler gauges. Equalize precisely. The most common operational problem.
Weak output arcPartial charging or stage failureIncrease charge time. Check for surface tracking on insulation. Test each stage individually.
Erratic firing patternContaminated spark gapsClean brass spheres with fine abrasive. Remove oxidation. Low humidity environment helps significantly.
Discharge to ground pipe instead of electrodeInsufficient clearanceIncrease separation between stack and ground pipe. Adjust output electrode height.
Component arcing overInsufficient creepage distanceIncrease spacing. Check for sharp metal edges. Verify no copper traces in the field path.
EMI and Interference
Effect ObservedSeverityResponse
Radio or TV static during dischargeNormalMarx is a broadband RF source. Expected and unavoidable.
Fluorescent lights flickeringNormalConfirms successful discharge. Consider it a performance indicator.
Nearby electronics resettingInvestigateIncrease separation. Add ferrite beads on nearby power cables.
Ground fault interrupters trippingInvestigateVerify Marx ground is fully isolated from building ground. Check for unintended ground connections.
Neighbor electronics affectedLimit operationAvoid operating near medical equipment. Inform neighbors of test schedule.
Diagnostic Test Points — Power OFF, All Caps Discharged
TP1
MOT Primary Input
120V AC
TP2
MOT Secondary Output
15–20V AC
TP3
After Bridge Rectifier
21–28V DC
TP4
ZVS Driver Input
Matches TP3
TP5
Flyback HV Output
~10kV DC
TP6
Capacitor 1 (Top Terminal)
Matches TP5 after charge
TP7
Each Subsequent Cap
Verify charging
TP8
Output Electrode
Highest voltage point
TP9
Ground Rail to All Gaps
<1Ω continuity
1.9 Bill of Materials
BILL OF MATERIALS

Complete parts list for the 14-stage Marx generator. Prices approximate and subject to change. Salvage where possible — especially the MOT.

// High-Voltage Components
ItemSpecificationQtySourceEst. Cost
Doorknob Capacitor780 pF, 30kV ceramic14surplussales.com$140–200
Charging Resistor1MΩ, HV rated30eBay / electronics suppliers$30–50
Brass Electrode BallsM3 threaded, 8–10mm28Amazon B0C1Y97R11$15–20
Copper Wire (spark gaps)12 AWG solid bare50 ftHardware store$15–25
HV Output Wire10–18 AWG, HV insulation rated25 ftElectronics supplier$20–30
// Power Supply Components
ItemSpecificationQtySourceEst. Cost
ZVS Driver + Flyback Combo12–30V input, ~10kV output1Amazon$20–30
Microwave Oven Transformer1–1.5kVA heavy iron-core1Salvage / thrift stores$0–15
Bridge Rectifier35A, 200V rated1Electronics supplier$5–10
Secondary Winding Wire#12 AWG stranded20 ftHardware store$10–15
AC Flyback (alternate)25kV AC output1 (opt)hv-experimental.com$30–50
// Structural and Hardware
ItemSpecificationQtySourceEst. Cost
Polycarbonate Tube3" OD, 39" minimum length1Amazon B09LFQ5PL6$30–50
Base Plate¼" polycarbonate, 24"×18"1Plastics supplier / hardware$20–35
Copper Pipe (ground rail)½" diameter, 42" length1Hardware / plumbing$8–15
Plumbing Stub-Out Fitting½" copper1Hardware store$5–8
Ring Terminal AssortmentInsulated, multiple sizes1 pkgAmazon B0CP5Q2PJP$10–15
Heat Shrink TubingAssorted sizes, 2:1 ratio1 kitElectronics supplier$10–15
// Total Project Cost
CategoryCost Range
High-Voltage Components$220–325
Power Supply Components$65–100
Structural Components$85–135
Hardware and Fasteners$60–95
3D Printed Components (filament)$21–30
TOTAL — MATERIALS ONLY$451–685

Costs can be reduced significantly by salvaging components (MOT from a discarded microwave is free, copper wire and hardware from hardware stores). Many builders complete similar projects under $300 through judicious sourcing. The MOT is the single most expensive-to-buy but easiest-to-find-free component in the design.

1.10 References and Further Reading
REFERENCES
Essential Video Resources
ELECTRICAL SAFETY DEMONSTRATION →

Humorous but instructive. Every "ouch" represents a circumstance that could have been fatal. Required viewing before beginning any high-voltage work. Watch it twice.

MARX GENERATOR THEORY AND OPERATION →

Comprehensive explanation of circuit topology, operating principles, and design considerations. Good for all levels.

COMPLETE MOT REWINDING TUTORIAL →

Step-by-step guide to removing the MOT secondary and installing a custom winding. Watch before attempting the rewind.

BUILDING A 6kV POWER SUPPLY FROM A SINGLE MOT →

Demonstrates building a high-voltage power supply directly from a rewound MOT for Marx generator applications.

CUSTOM HV TRANSFORMER — SHATTERS ALL VOLTAGE RECORDS →

Advanced techniques for building ultra-high-voltage transformers from scratch. Relevant to HV-004.

Advanced Physics and Research Connections
PODKLETNOV'S IMPULSE GRAVITY GENERATOR →

Discussion of the theoretical connection between high-voltage impulse generators and gravitational effects. Controversial but experimentally interesting — the kind of thing Section 7 exists to explore.

TONY ROBERTSON — PODKLETNOV REPLICATION WORK →

Practical implementation and testing of impulse gravity modification experiments. Small scale but methodical.

DR. CHANCE GLENN — SMALL-SCALE GRAVITATIONAL ANOMALY TESTING →

Careful small-scale testing of gravitational anomalies in high-voltage impulse systems.

PAIS PATENTS — US20170313446A1 →

US Patent describing high-frequency gravitational wave generation concepts using electromagnetic fields. Describes similar principles in modern patent terminology.

ALZOFON — GRAVITY CONTROL WITH PRESENT TECHNOLOGY →

ISBN: 9781548293154. Theoretical framework for gravity modification using electromagnetic fields including radar and microwave systems.

Component Sources
ComponentSupplierNotes
HV Doorknob Capacitorssurplussales.comSurplus Sales of Nebraska — excellent HV component source, well-priced
AC Flyback Transformer (25kV)hv-experimental.comPurpose-built for serious high-voltage work
M3 Brass Electrode BallsAmazon B0C1Y97R11Threaded brass spheres ideal for spark gap electrodes
Insulated Ring TerminalsAmazon B0CP5Q2PJPAssorted sizes for all connection points
3" Polycarbonate TubeAmazon B09LFQ5PL6Clear polycarbonate tube for backbone structure
Books and Textbooks
Foundations of Pulsed Power Technology — Shipman et al.
The authoritative textbook on pulse power systems. Comprehensive treatment of Marx generators, energy storage, and switching. Essential for serious practitioners.
High Voltage Engineering Fundamentals — Kuffel and Zaengl
Classic reference covering Paschen's Law, dielectric breakdown, insulation coordination, and testing methodology. Standard reference for HV design.
Pulsed Power — Guenther and Kristiansen
Advanced treatment of Marx generators, pulse-forming networks, and high-power switching. Graduate-level technical depth.
Standards and Safety References
  • ▸
    NFPA 70E — Electrical Safety in the Workplace — arc flash hazard analysis methodology
  • ▸
    IEEE 1584 — Guide for Performing Arc-Flash Hazard Calculations
  • ▸
    IEC 60664-1 — Insulation Coordination for Equipment within Low-Voltage Systems
Communities
  • ▸
    4HV.org — The high-voltage community forum. Decades of collective knowledge from experienced builders worldwide.
  • ▸
    r/highvoltage — Reddit community for HV enthusiasts of all levels
  • ▸
    Physics Forums — High Energy Physics and Theory sections for academic depth and peer review
  • ▸
    Hackaday.io — High voltage project documentation, active community
Acknowledgments

This chapter builds on decades of work by countless engineers, physicists, and amateur experimenters. Special acknowledgment to Erwin Marx for the original circuit topology (1924) — one of the most elegant solutions in electrical engineering. To the high-voltage amateur community for open sharing of designs and hard-won experience. To YouTube educators who make complex topics accessible. And to surplus electronics dealers who keep obsolete but irreplaceable components available.

⚠️
FINAL LEGAL DISCLAIMER The information in this document is provided for educational and research purposes only. The author, SpaceCommsKit, and associated parties make no warranties regarding accuracy, completeness, or suitability of this information, and assume no liability for injury, death, property damage, or any other loss resulting from its use. Do not proceed without appropriate training, equipment, insurance, and legal authority. YOU PROCEED ENTIRELY AT YOUR OWN RISK.
// END OF CHAPTER 1
MARX GENERATOR V1
HV-001 · PUBLICATION VERSION 1.0 · OCTOBER 2025 · SPACECOMMSKIT · TENNESSEE, USA
⚡ UNLOCK FULL BUILD DOCS
PATREON TIER 2 · $10/MONTH
⬇ DOWNLOAD STL FILES
GOOGLE DRIVE · PATREON EXCLUSIVE
// Quick Specs
TOPOLOGYMarx Bank
STAGES14
CAPACITOR780pF / 30kV
CHARGE VOLTAGE10kV / stage
THEORETICAL V140 kV
ACTUAL V100–120 kV
STORED ENERGY0.55 J
CHARGE TIME τ~1.6 sec
BACKBONE3" Poly tube
PSURewound MOT
FRAME MATERIALPETG 3D Print
BUILD COST$451–685
// Patreon Content
  • ✓Full assembly photographs
  • ✓Exact component values and wiring
  • ✓Gap adjustment procedure in detail
  • ✓Test results and arc photographs
  • ✓Complete BOM with exact sourcing
  • ⬇Capacitor mount frame STL
  • ⬇Base mount disc STL
  • ⬇Tube cap STL
  • ⬇Electrode arm assemblies STL (×2)
  • ⬇Ground pipe support block STL
// Safety Quick Ref
☠Never work alone — ever
☠Always discharge all caps first
☠Verify zero V with HV probe
⚡Class 2 gloves — 17kV rated min
⚡Face shield + ANSI Z87.1 glasses
⚡CO₂ extinguisher within reach
✓HV ground isolated from building
✓3ft min clearance all sides
✓Emergency shutoff within reach